A refrigerated container or truck can look perfectly normal when its doors open at your dock. The fruit may feel cold and the display may show the right set point. What it cannot show is what happened over the previous days: a power cut at the port, a long stop with the unit off, a warm corner near the door. A temperature data logger records that history, and learning to read its trace is one of the most useful skills a produce buyer can have.
Why time and temperature both matter
The USDA's handbook on protecting perishable foods in transport makes a simple point: quality loss is a function of both time and temperature, and abuse is additive. Short spells of warmth during loading, transit and unloading add up, and the loss may only show at the store or on the plate.
Temperature can also go wrong in the other direction. Fruit and vegetables can be damaged by freezing, and many tropical and subtropical crops suffer chilling injury at temperatures well above freezing. Symptoms such as pitting, discolouration, failure to ripen and off-flavours may not appear until days later. A trace is often the only way to connect that damage to its cause.
How a reefer moves air
To read a trace you need a rough picture of airflow. In a marine reefer container, the refrigeration unit draws warm air from just below the ceiling, cools it and blows it along the T-shaped floor channels. The cold air rises up through the cargo and returns to the unit. Highway trucks may use either bottom-air delivery or top-air delivery, where air is blown along the ceiling.
This creates two temperatures the unit itself measures:
- Supply (delivery) air: the air leaving the unit, the coldest point in the system.
- Return air: the air coming back after passing through the load.
Germany's insurance-industry cargo guidance (TIS-GDV) notes that the traditional chart recorder in a reefer usually logs return air, because it gives a better picture of the cargo's condition. Modern units store both readings in their controller, which can be downloaded at the end of a voyage.
The load is not one temperature
The most important lesson from research is that temperatures inside a container vary from place to place.
- Researchers at Wageningen University, studying grape shipments from South Africa to the Netherlands with 31 loggers spread through each container, note that cargo at the door end is usually up to 2 °C warmer than the supply air.
- A University of Bremen review of container and truck studies, presented at a Cool Chain Association workshop, reported spatial differences of 5 °C or more in some measurements, and cited kiwifruit firmness varying by a factor of two to three depending on position.
- In the same group's truck trials, the difference between the coldest and warmest points ranged from about 2.5 °C to 6 °C, driven by refrigeration on/off cycles, distance from the unit, outside temperature and door openings.
Ambient heat makes this worse. The Wageningen team found temperature gradients inside containers tend to be largest when outside temperatures are highest, which is a useful thing to remember for summer deliveries across much of India.
Where loggers should sit
Because the load is not uniform, one logger tells you about one spot. TIS-GDV suggests placing recorders at the risk points, such as inside the packaging or in the top layer near the door. The Bremen work concluded that reliable monitoring of the whole load needs several measuring points, as individual loggers in the same zone can behave quite differently.
A practical approach for buyers:
- At least one logger near the door end, in the upper layers, where cargo tends to run warmest.
- One near the front (unit end), where cargo is closer to supply air and most at risk of chilling or freezing.
- Inside a carton, not taped to a wall, if you want product temperature rather than air temperature.
- The same positions every time, so traces from different loads can be compared.
Logging interval and accuracy
Loggers record at a fixed interval. If the interval is too long, short events disappear between readings. The Bremen researchers noted that a reading every ten minutes was typical in their experiments and that at least two readings are needed within each temperature cycle to see it at all.
Accuracy matters too. Small differences between positions are only meaningful if the loggers themselves are accurate and calibrated. Ask what accuracy your supplier's loggers are rated for, and when they were last checked.
How to read the trace
A typical trace for a well-handled load of precooled produce has a recognisable shape. Here is what to look for:
What you see | What it may mean |
|---|---|
Flat line close to the set point | Good control; product was likely precooled |
Slow fall over many hours at the start | Product was loaded warm and the unit is pulling it down |
Regular small saw-tooth | Normal refrigeration or defrost cycles |
Sharp rise, then recovery | Door opening, unit stop or power break, such as at a port or transfer point |
Steady climb that does not recover | Unit fault, blocked airflow or excess heat load |
Dips below the safe minimum | Risk of chilling or freezing, especially near the supply air |
Big gap between door-end and front loggers | Poor airflow through the load |
The warm start
The USDA handbook notes that most truck refrigeration units have enough reserve capacity to remove a reasonable amount of extra heat, but if product is loaded well above its transit temperature the whole heat load needs to be estimated, and a unit that cannot handle it should not be used. The ideal, it says, is to accept only properly precooled product. A slow initial fall on the trace is a sign that precooling was skipped or incomplete.
Spikes
A single short spike is often harmless, but repeated ones add up. Note when they happened and match them to the shipment's events, such as port handover, customs inspection, transfer to a truck or a delivery stop.
Too cold
Readings below the recommended range matter as much as warm ones for chilling-sensitive produce. The USDA handbook warns that freezing can occur in the part of the load closest to where cold air leaves the unit. If a front logger shows sub-zero readings, inspect those cartons closely.
Ask for more than one record
A trace from a single logger is useful, but it is stronger evidence alongside other records. For an imported container, ask for:
- the reefer unit's controller download (supply and return air over the voyage);
- the set point and any fresh-air or ventilation settings used;
- the in-cargo logger traces, with their positions;
- pulp temperature readings taken at loading and at arrival.
The TIS-GDV guidance notes that fresh-air exchange matters for respiring fruit, because it removes carbon dioxide and ethylene. A setting that suits one commodity may not suit another in a mixed load.
What to check at your dock
- Check the logger before unloading. If it has an alarm indicator for limits crossed, note its status.
- Take pulp temperatures from cartons at the door end and deeper in the load, top and bottom layers.
- Download or photograph the trace and file it with the delivery note and invoice.
- Inspect suspect cartons for chilling, freezing, condensation or early ripening.
- Raise issues on the day, with the trace attached, so your supplier can trace the cause.
Questions to ask any supplier
- Do your trucks and containers carry independent loggers, and where are they placed?
- What logging interval and accuracy do they have?
- Can you share the trace for my delivery on request?
- Is product precooled before loading, and how do you confirm it?
- What happens when a trace shows an excursion?
A trace turns arguments about quality into a conversation about facts. If you would like to discuss cold-chain handling and delivery for your locations, ask ORIGO for today's availability and a quote through the contact page.
Sources
- Ashby, B. H., "Protecting Perishable Foods During Transport by Truck", USDA Agriculture Handbook No. 669: https://ageconsearch.umn.edu/record/321862/files/AH669rev.pdf
- TIS Transport Information Service (GDV), container and reefer guidance: https://www.tis-gdv.de/?p=11942
- Lukasse, L. J. S., Staal, M. G., Wissink, E. B., "An airflow enhancing floor cover to improve temperature uniformity in maritime refrigerated containers", Wageningen Food and Biobased Research (ICR 2019): https://edepot.wur.nl/513463
- Jedermann, R., "Temperature measurements: when, where and how?", University of Bremen, Cool Chain Association workshop, 2006: https://icia.uni-bremen.de/fileadmin/Redakteure/pdfs/2006/RJ_CCA_Knivsta_15.pdf